"Requested_prod_id","Requested_GTIN(EAN/UPC)","Requested_Icecat_id","ErrorMessage","Supplier","Prod_id","Icecat_id","GTIN(EAN/UPC)","Category","CatId","ProductFamily","ProductSeries","Model","Updated","Quality","On_Market","Product_Views","HighPic","HighPic Resolution","LowPic","Pic500x500","ThumbPic","Folder_PDF","Folder_Manual_PDF","ProductTitle","ShortDesc","ShortSummaryDescription","LongSummaryDescription","LongDesc","ProductGallery","ProductGallery Resolution","ProductGallery ExpirationDate","360","EU Energy Label","EU Product Fiche","PDF","Video/mp4","Other Multimedia","ProductMultimediaObject ExpirationDate","ReasonsToBuy","Spec 1","Spec 2","Spec 3","Spec 4","Spec 5","Spec 6","Spec 7","Spec 8","Spec 9","Spec 10","Spec 11","Spec 12","Spec 13","Spec 14","Spec 15","Spec 16","Spec 17","Spec 18","Spec 19","Spec 20","Spec 21","Spec 22","Spec 23","Spec 24","Spec 25","Spec 26","Spec 27","Spec 28","Spec 29","Spec 30","Spec 31","Spec 32","Spec 33","Spec 34","Spec 35","Spec 36","Spec 37","Spec 38","Spec 39","Spec 40","Spec 41","Spec 42","Spec 43","Spec 44","Spec 45","Spec 46","Spec 47","Spec 48","Spec 49","Spec 50","Spec 51","Spec 52","Spec 53","Spec 54","Spec 55","Spec 56","Spec 57","Spec 58","Spec 59","Spec 60","Spec 61","Spec 62","Spec 63","Spec 64","Spec 65","Spec 66","Spec 67","Spec 68","Spec 69","Spec 70","Spec 71","Spec 72","Spec 73","Spec 74","Spec 75","Spec 76","Spec 77" "","","79455705","","Tripp Lite","SU2000RTXLCD2U","79455705","0037332248534|037332248534","Uninterruptible Power Supplies (UPSs)","817","","","120V 2000VA 1.8kW Double-Conversion UPS - 7 Outlets, Extended Run, Card Slot, LCD, USB, DB9, 2U","20221009171248","ICECAT","1","46120","https://images.icecat.biz/img/gallery/79455705_9222745020.jpg","1200x1200","https://images.icecat.biz/img/gallery_lows/79455705_9222745020.jpg","https://images.icecat.biz/img/gallery_mediums/79455705_9222745020.jpg","https://images.icecat.biz/img/gallery_thumbs/79455705_9222745020.jpg","http://objects.icecat.biz/objects/mmo_79455705_1594911635_6691_31305.pdf","","Tripp Lite SU2000RTXLCD2U uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA 1800 W 7 AC outlet(s)","120V 2000VA 1.8kW Double-Conversion UPS - 7 Outlets, Extended Run, Card Slot, LCD, USB, DB9, 2U","Tripp Lite SU2000RTXLCD2U, Double-conversion (Online), 2 kVA, 1800 W, Pure sine, 100 V, 127 V","Tripp Lite SU2000RTXLCD2U. UPS topology: Double-conversion (Online), Output power capacity: 2 kVA, Output power: 1800 W. AC outlet types: NEMA 5–20R, NEMA L5-20R, Power plug: NEMA 5-20P, AC outlets quantity: 7 AC outlet(s). Typical backup time at full load: 4,3 min, Typical backup time at half load: 12,3 min. Form factor: Rackmount, Product colour: Black, Housing material: Steel. Width: 444,5 mm, Depth: 482,6 mm, Height: 88,9 mm","Double-Conversion UPS Protects Equipment against Damage, Downtime and Data Loss\nThis 100/110/120/127V 50/60 Hz UPS system with IGBT technology maintains perfect output by converting AC input to DC, then reconverting UPS output to fully regulated sine wave AC with +/-2% voltage regulation in online and battery modes. Featuring an 1800W capacity, high 0.9 power factor, 570 joules of surge suppression, true on-line operation with pure sine wave output and zero transfer time to battery mode in on-line double-conversion mode, the SmartOnline® SU2000RTXLCD2U double-conversion UPS provides the highest level of AC power protection and battery backup for critical network closet, computer room and data center equipment.\n\nIndividually Controllable Load Banks Let You Access and Control Outlets Remotely\nSix NEMA 5-15/20R outlets are split evenly into two switchable three-outlet load banks, allowing you to reboot select components or shed loads remotely. In addition to those six outlets, this UPS provides one unswitched NEMA L5-20R outlet for powering a critical component or in-rack PDU.\n\nReliable, Expandable Battery Backup Keeps You Operational Through Power Outages\nThe field-replaceable, hot-swappable internal battery provides 13.3 minutes of support at half load (900W) and 4.3 minutes at full load (1800W), keeping protected equipment operational through power failures. For mission-critical applications demanding scalable extended runtime, the UPS supports external battery packs, such as Tripp Lite’s BP48V27-2US (sold separately). The intelligent battery management system with temperature-compensated charging extends battery life.\n\nENERGY STAR-Certified Economy Mode Helps You Save Money and Protect the Environment\nBy meeting strict EPA efficiency guidelines, this ENERGY STAR-certified UPS system helps you save money and energy. A power-saving Economy mode setting option offers enhanced efficiency and reduced BTU output when utility power is already high quality.\n\nSet Output Frequency to Match That of Your Connected Equipment\nUsing the UPS in Frequency Conversion mode will correct or convert the incoming frequency of 50 Hz to output 60 Hz (and vice versa).\n\nIntuitive Front-Panel Interface for Convenient UPS Operation and Monitoring\nThe front-panel LCD features nine selectable screens of UPS data (including load, voltage and battery data) and 16 screens of configuration and setup options. LEDs indicate line power availability, AC to DC conversion, battery mode operation, inverter mode, ECO mode operation, bypass mode operation and AC output status.\n\nAdvanced Communications Ports Allow for Automatic Saves and Shutdowns\nRS-232 and HID-compliant USB ports connect to a computer running Tripp Lite’s free downloadable PowerAlert® software to enable safe unattended file saves and system shutdown in case of a prolonged power failure. An EPO port connects the UPS to a contact closure switch to enable emergency inverter shutdown. Cables are included.\n\nOptional WEBCARDLX Network Interface Offers 24/7 Access\nThe SU2000RTXLCD2U includes a slot for an optional Java-free HTML5-based WEBCARDLX (sold separately) that enables full remote access for site power and UPS status monitoring, configuration, control and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Automated alerts help prevent accidental overloads, power loss and downtime. WEBCARDLX 15.5.2 or later is required to use the Auto Probe feature, which can prevent costly service calls by automatically rebooting non-responsive network devices.\n\nVersatile Installation Options\nHardware is included for mounting the UPS system in 2U of space in an EIA-standard 19-inch 4-post rack. Use the optional 2POSTRMKITWM (sold separately) for 2-post rack mounting or the optional 2-9USTAND (sold separately) for mounting in an upright tower position. The 10-foot power cord with NEMA 5-20P plug connects to any compatible AC outlet.","https://images.icecat.biz/img/gallery/79455705_9222745020.jpg|https://images.icecat.biz/img/gallery/79455705_1559339840.jpg|https://images.icecat.biz/img/gallery/79455705_0868030538.jpg|https://images.icecat.biz/img/gallery/79455705_0853711238.jpg|https://images.icecat.biz/img/gallery/79455705_0753450268.jpg|https://images.icecat.biz/img/gallery/79455705_8369453684.jpg|https://images.icecat.biz/img/gallery/79455705_4696545766.jpg","1200x1200|1200x1200|1200x1200|1200x1200|1200x1200|1200x1200|1200x1200","||||||","","","","","","","","","Features","UPS topology: Double-conversion (Online)","Output power capacity: 2 kVA","Output power: 1800 W","Waveform: Pure sine","Input operation voltage (min): 100 V","Input operation voltage (max): 127 V","Input frequency: 50/60 Hz","Output operation voltage (min): 100 V","Output operation voltage (max): 127 V","Output frequency: 50/60 Hz","Output voltage regulation: 2%","Maximum current: 16 A","Surge energy rating: 570 J","Number of input phases: 1","Efficiency (ECO mode): 94%","Power factor: 0,9","Crest factor: 3:1","Emergency Power Off (EPO): Yes","EMI/RFI noise filtering: Yes","Noise level: 57 dB","Surge protection features: Digital Subscriber Line (DSL), Network, Telephone","Power protection features: Over voltage, Under voltage","Audible alarm(s): Yes","Audible alarm modes: Alarm when on battery, Fault, Low battery alarm, Overload alarm","Country of origin: China","Ports & interfaces","AC outlet types: NEMA 5–20R, NEMA L5-20R","Power plug: NEMA 5-20P","AC outlets quantity: 7 AC outlet(s)","USB port: Yes","Serial interface: Yes","Serial interface type: RS-232","Ethernet LAN (RJ-45) ports: 2","Emergency Power Off (EPO) connector: Yes","Battery","Typical backup time at full load: 4,3 min","Typical backup time at half load: 12,3 min","Hot-swap battery: Yes","Cold start: Yes","Design","Form factor: Rackmount","Product colour: Black","Housing material: Steel","Rack capacity: 2U","Cable length: 3,1 m","Cooling type: Active","Built-in fan: Yes","Display type: LCD","LED indicators: Yes","Certification: FCC Part 15 Category A (EMI)\nCSA (Canada)\nNOM (Mexico)\nUL1778 (USA)","Operational conditions","Operating temperature (T-T): 0 - 40 °C","Storage temperature (T-T): -15 - 50 °C","Operating relative humidity (H-H): 0 - 95%","Operating altitude: 0 - 3000 m","Technical details","Sustainability certificates: RoHS, ENERGY STAR","Weight & dimensions","Width: 444,5 mm","Depth: 482,6 mm","Height: 88,9 mm","Weight: 22 kg","Package width: 589,3 mm","Package depth: 490,2 mm","Package height: 231,1 mm","Package weight: 27,2 kg","Packaging data","Rack mount kit: Yes","Cables included: RS-232, USB cable","Manual: Yes","Logistics data","Master (outer) case width: 589,3 mm","Master (outer) case length: 490,2 mm","Master (outer) case height: 231,1 mm","Master (outer) case weight: 27,2 kg","Quantity per master (outer) case: 1 pc(s)"