APC NetShelter Rack PDU Advanced power distribution unit (PDU) 48 AC outlet(s) 0U Black

  • Brand : APC
  • Product name : NetShelter Rack PDU Advanced
  • Product code : APDU10350MO
  • GTIN (EAN/UPC) : 0731304439738
  • Category : Power Distribution Units (PDUs)
  • Data-sheet quality : created/standardized by Icecat
  • Product views : 28463
  • Info modified on : 11 Mar 2024 09:14:46
  • APC APDU10350MO user manual (4.4 MB) NetShelter Rack PDU Advanced Installation & Quick Start (2.0 MB) APC NetShelter Rack PDU Advanced Brochure (1.0 MB) End User Brochure APC NetShelter Rack PDU Advanced (2.2 MB) 1 Pager with specs APC NetShelter Rack PDU Advanced (0.4 MB) APDU10350MO-APC NetShelter Rack PDU Advanced Metered Outlet 17.3kW 3PH 415V 30A 530P6_48 Outlet (0.5 MB)
  • Bullet Points APC NetShelter Rack PDU Advanced power distribution unit (PDU) 48 AC outlet(s) 0U Black :
    • - Metered Outlet, 17.3kW, 3PH
    • - 415V, 30A, 530P6
    • - 48 Outlet
    • - Power metering via remote access
    • - High Density
    • - Availability
    • - Agility
    • - Manageability
  • Warranty: : 3 years repair or replace
  • Long product name APC NetShelter Rack PDU Advanced power distribution unit (PDU) 48 AC outlet(s) 0U Black :

    APC NetShelter Rack PDU Advanced, Metered Outlet, 17.3kW, 3PH, 415V, 30A, 530P6, 48 Outlet

  • APC NetShelter Rack PDU Advanced power distribution unit (PDU) 48 AC outlet(s) 0U Black :

    APC NetShelter Rack PDU Advanced, Metered Outlet, 17.3kW, 3PH, 415V, 30A, 530P6, 48 Outlet
    APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. Outlet and PDU level power metering for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 48 outlets in a 2.2" wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. For data center deployments across multiple regions, these PDUs are both UL and CE rated providing one PDU that can be used globally to simplify and standardize deployment.

    Maximum Outlet Density
    All models include 40, 42, or 48 outlets to accommodate even the highest density of devices, allow for more installation flexibility, and provide room for growth within the PDUs power capacity limits.
    Space Saving
    With such high outlet counts and power capacity, NetShelter Advanced Rack PDUs are designed to maximize space with their single width form factor, often allowing for fewer PDUs to accommodate the same number of devices and power requirements.
    High Power Capacity
    Models now available to provide up to 34.6kW (derated to 80% capacity per National Electric Code (NEC) for North America) and up to 43.5kW for other countries to ensure support for most any density deployment and help minimize the number of PDUs needed to do so.

    APC Locking Power Cord Compatible
    Free up space and secure power cords between rack-mount PDUs and attached IT equipment with this easy-to-use cord retention method. Optional AP8700 power cords will fit into any standard IEC receptacle or power inlet; the "locking" feature is enabled when used with NetShelter Rack PDU Advanced to reduce the probability of accidental power cord disconnect.
    Circuit Breaker Monitoring
    Allows total load across each circuit breaker to be monitored for potential overload and can be configured to provide notification in the event of a circuit breaker trip.
    Alternating Phase
    NetShelter Rack PDU Advanced incorporates an alternating phase design on 3 phase models whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU. This alternating phase layout facilitates better power cord management and more intuitive load balancing versus traditional PDU solutions where outlets are grouped by phase at the top, middle, and bottom of the PDU.
    60ºC (140ºF) Operating Temperature
    Rated and approved to operate up to 60C (140F) at full load, NetShelter Rack PDU Advanced ensures reliability and availability even in today's high density deployments.
    Power Sharing
    Rack PDUs cascaded together via the two ethernet ports on each PDU allow Network Management Cards (NMC) to continue functioning in the event of an AC power loss to a given PDU. Network communication is uninterrupted, attached sensors still operate, and alarm traps remain available.
    Hydraulic Magnetic Circuit Breakers
    Provide increased availability by maintaining trip current over a wide temperature range.
    Live Swap Network Management Card
    The Network Management Card (NMC) can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event.
    Color Coded Outlets
    To simplify deployment, outlets on the PDUs are color coded by breaker on 1 phase models and color coded and/or labeled by breaker and input phase on 3 phase models.
    Environmental Sensor Support
    Two environmental sensor ports allow for optional sensors (sold separately) to be connected. Sensors available within the NetSelter Rack PDU Advanced portfolio include temperature, temperature/humidity, temperature (3 sensors)/humidity, rope leak detection, and a door contact switch. Also available is an expansion hub to allow connection of up to three sensors providing the ability to manage six separate sensors from one rack PDU. Sensor availability expected late 2022.

    Wide Offer Breadth
    Metered, Switched, and Metered-by-Outlet with Switching functionality are available across all power configurations ranging from 5kW up to 34.6kW to meet the need for most deployments.
    Network Cascading
    Connect and manage up to 32 PDUs from a single IP address to simplify and speed PDU deployment while reducing networking costs associated with having a dedicated network connection for each PDU.
    US Based Manufacturing
    US based manufacturing enables better product availability and ability to offer configure-to-order (CTO) products (optional and subject to pricing and leadtimes) including different cord lengths, plug types, and PDU chassis color.
    Dual Rated
    For data center deployments across multiple regions, select models are both UL and CE rated providing one PDU that can be used globally to simplify and standardize deployment.
    Flexible PDU Mounting
    With pre-installed mounting pegs, NetShelter Rack PDU Advanced can be quickly installed in the toolless mounting holes of the rear accessory channel in a NetShelter SX and many 3rd party cabinets. Mounting pegs can be repositioned to the side of the PDU to rotate the orientation of the outlets 90 degrees and face the back of the cabinet for better clearance from device chassis or mounting rails.
    4-in-1 Combination Outlets
    Offering unparalleled flexibility, 4-in-1 combination outlets which can be used as either C13 or C19 enable a single PDU outlet layout to support various rack layouts and configurations. In addition, the same 4-in-1 combination outlets also serve as high temperature C15 and C21 outlets for devices with C16 and C22 power cords. With 4-in-1 combination outlets redeployment of a PDU with new rack layout or configuration is easy and straightforward, often preventing the need to remove and discard a PDU upon IT refresh.

    Color LCD Display
    NetShelter Rack PDU Advanced provides a rich color LCD display for local management and control at the rack.
    Dual Network Ports
    A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy.
    1% Metering Accuracy
    Providing the same level of accuracy as a utility company meter by adhering to IEC 62053-21 class 1, 1% metering accuracy provides peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring.
    Gigabit Ethernet Connectivity
    Provides Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center.
    Network Management Capabilities
    Full-featured network management interfaces that provide standards-based management via Web and SNMP. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time.

  • Short summary description APC NetShelter Rack PDU Advanced power distribution unit (PDU) 48 AC outlet(s) 0U Black :

    APC NetShelter Rack PDU Advanced, Metered, Metered-by-outlet, 0U, Three-phase, Rackmount, Vertical, Black

  • Long summary description APC NetShelter Rack PDU Advanced power distribution unit (PDU) 48 AC outlet(s) 0U Black :

    APC NetShelter Rack PDU Advanced. PDU types: Metered, Metered-by-outlet, Rack capacity: 0U, Type: Three-phase. AC outlets quantity: 48 AC outlet(s), AC outlet types: C13 coupler, C15 coupler, C19 coupler, C21 coupler, Power plug: IEC 60309. LED indicators: Activity, Network, Power, Cable length: 1.8 m, Security algorithms: 128-bit AES, 192-bit AES, 256-bit AES, DES, MD5, SNMP, SNMPv2, SNMPv3. Monitoring: Current, Humidity, Power, Temperature, Voltage, Outlet control: Lock-out, Recycle, Turn off, Turn on, Firmware upgradeable via: Network, USB. Nominal input voltage: 400 V, Maximum current: 32 A, AC input frequency: 50 - 60 Hz

Specs
Design
PDU types Metered, Metered-by-outlet
Type Three-phase
Form factor Rackmount
Rack capacity 0U
Mounting Vertical
Product colour Black
Display LCD
On/off switch
Regulatory Approvals CE, CSA C22.2 No 62368-1, EN 62368-1, FCC part 15 subpart B, UKCA, UL 62368-1
Ports & interfaces
AC outlets quantity 48 AC outlet(s)
Power plug IEC 60309
AC outlet types C13 coupler, C15 coupler, C19 coupler, C21 coupler
Ethernet LAN (RJ-45) ports 2
USB ports quantity 1
Features
Daisy chain
Reset button
LED indicators Activity, Network, Power
Surge protection
Colour-coded outlets
Cable length 1.8 m
Security algorithms 128-bit AES, 192-bit AES, 256-bit AES, DES, MD5, SNMP, SNMPv2, SNMPv3
Password protection
Compatible products Compatible with most NetShelter SX enclosures and third-party racks
Management features
Monitoring Current, Humidity, Power, Temperature, Voltage
Outlet control Lock-out, Recycle, Turn off, Turn on
Firmware upgradeable
Firmware upgradeable via Network, USB

Power
Nominal input voltage 400 V
AC input frequency 50 - 60 Hz
Maximum current 32 A
Nominal output voltage 230 V
Load capacity 22100 VA
Number of phases 3
Power protection features Overload
Maximum power 22100 W
Weight & dimensions
Width 56 mm
Depth 75 mm
Height 1780 mm
Weight 9.6 kg
Packaging data
Package weight 12.6 kg
Package width 262 mm
Package depth 132 mm
Package height 1980 mm
Operational conditions
Operating temperature (T-T) -5 - 60 °C
Storage temperature (T-T) -25 - 65 °C
Operating relative humidity (H-H) 5 - 95%
Storage relative humidity (H-H) 5 - 95%
Operating altitude 0 - 3048 m
Non-operating altitude 0 - 15240 m
Operating temperature (T-T) 23 - 140 °F
Technical details
Sustainability certificates RoHS
Distributors
Country Distributor
5 distributor(s)
2 distributor(s)
3 distributor(s)
2 distributor(s)
2 distributor(s)
3 distributor(s)
6 distributor(s)
3 distributor(s)
2 distributor(s)
3 distributor(s)
3 distributor(s)
2 distributor(s)
1 distributor(s)
1 distributor(s)
1 distributor(s)
1 distributor(s)
1 distributor(s)